Exponent Monitoring For Low-Cost Concurrent Error Detection In Fpu Control Logic

2011 IEEE 29TH VLSI TEST SYMPOSIUM (VTS)(2011)

引用 11|浏览9
暂无评分
摘要
We present a non-intrusive concurrent error detection (CED) method for protecting the control logic of a contemporary floating point unit (FPU). The proposed method is based on the observation that control logic errors lead to extensive datapath corruption and affect, with high probability, the exponent part of the IEEE 754 floating point representation. Thus, exponent monitoring can be utilized to detect errors in the control logic of the FPU. Predicting the exponent involves relatively simple operations, therefore our method incurs significantly lower overhead than the classical approach of duplicating the control logic of the FPU. Indeed, experimental results on the openSPARC T1 processor show that, as compared to control logic duplication, which incurs an area overhead of 17.9% of the FPU size, our method incurs an area overhead of only 5.8% yet still achieves detection of over 95% of transient errors in the FPU control logic. Moreover, the proposed method offers the ancillary benefit of also detecting 98.1% of datapath errors that affect the exponent, which cannot be detected via duplication of control logic. Finally, when combined with a classical residue code-based method for the fraction, our method leads to a complete CED solution for the entire FPU which provides a coverage of 94.4% of all errors at an area cost of 16.32% of the FPU size.
更多
查看译文
关键词
floating point,floating point arithmetic,floating point unit,logic circuits,registers,pipelines,assembly,error detection,hardware