Grey box modeling of first flush and incoming wastewater at a wastewater treatment plant

ENVIRONMETRICS(2000)

引用 22|浏览5
暂无评分
摘要
On-line measurements of turbidity, UV absorption and flow in the inlet to a Danish wastewater treatment plant are used to establish a dynamic model of the deposition of pollutants in the sewer system and the pollutant mass how to the treatment plant. The modelling is made using the grey box approach, which is a statistical method that uses known physical relations to formulate the model. The dynamics of the sewer are modelled by means of continuous time stochastic differential equations combined with dry weather diurnal pollutant mass flows. Copyright (C) 2000 John Wiley & Sons, Ltd.
更多
查看译文
关键词
on-line measurements,sewer systems,wastewater treatment plant,dynamic systems,grey box modelling,stochastic differential equations,first flush,diurnal pollutant load