The study of wavelength-dependent wavefront aberrations based on individual eye model

Optik(2008)

引用 12|浏览6
暂无评分
摘要
Theoretical calculations of the wavelength dependence of the ocular wavefront aberrations are performed with individual eye model. Individual eye model, based on the traditional Gullstrand–Le Grand eye model, has been established with measured individual cornea data, eyeball depth and wavefront aberrations. We analyze the wavelength-dependent wavefront aberrations at 12 different visible wavelengths (between 400 and 750nm) for eight eyes. The change of defocus with wavelength (longitudinal chromatic aberration, LCA) is noticeable, and in good agreement with the results from references. In most cases, the primary spherical aberration changes significantly with wavelength. In comparison with the primary spherical aberration, the other higher-order wavefront aberrations have a smaller change with wavelength. These results have potential applications in those situations where defocus or higher-order wavefront aberrations information in arbitrary wavelength is required.
更多
查看译文
关键词
Chromatic wavefront aberration,Visible spectrum,Individual eye model,ZEMAX