On the Best Condition of Electrolysis Coking Wastewater by Orthogonal Method.

ADVANCES IN COMPUTER SCIENCE, ENVIRONMENT, ECOINFORMATICS, AND EDUCATION, PT II(2011)

引用 0|浏览18
暂无评分
摘要
Coking wastewater was advanced treated by electrolytic experiment. Through the orthogonal method, we found out the optimum experimental condition as current density 20 mA/cm2, electrode plate span 1cm, electrolytic time 60 min, PH 7 and electrical conductivity 8000 mu s/cm. The removal rates of COD, NH3-N and phenol were 58.62%, 89.9% and 96.8% respectively and the corresponding concentrations were 97.78mg/L, 14.3mg/L and 0.43mg/L respectively, which can meet first discharge standard of GB 13456-1992.
更多
查看译文
关键词
The orthogonal method,electrolysis,coking wastewater,advanced treatment